Determination of iron(II) ion with a perfluorinated sulfonated polymer(nafion)-ethylenediamine(en) modified glassy carbon electrode was studied. It was based on the chemical reactivity of an immobilized layer(nafion-en) to yield complex $[Fe(en)_3]^{+2}$. The oxidation peak potential by differential pulse voltammetry(DPV) was observed at 0.340${\pm}$0.015 V(vs. Ag/AgCl). The linear calibration curve was obtained in iron(II) ion concentration range $5{\times}10^{-6}{\sim}0.2{\times}10^{-3} M(0.28{\sim}11.17\; mg/L)$, and the detection limit(3s) was $1.89{\times}10^{-5}$M(1.056 mg/L).
@article{ JCGMDC_2003_v47n2_115}
,title={Differential Pulse Voltammetric Determination of Iron(II) ion with a Nafion-Ethylenediamine Modified Glassy Carbon Electrode}
,volume={2}
, url={http://dx.doi.org/10.5012/jkcs.2003.47.2.115}, DOI={10.5012/jkcs.2003.47.2.115}
, number= {2}
, journal={Journal of the Korean Chemical Society}
, publisher={Korean Chemical Society}
, author={Kyong Wone, Kim
and
Hee Cheol, Kim
and
Sung-Hyun, Kim
and
Byung Ho, Park
and
Yeon Hee, Kim
and
Kyong Nam, Kim
and
Yong Chun, Ko}
, year={2003}
, month={Apr}
TY - JOUR
T2 - Journal of the Korean Chemical Society
AU - Kyong Wone, Kim
AU - Hee Cheol, Kim
AU - Sung-Hyun, Kim
AU - Byung Ho, Park
AU - Yeon Hee, Kim
AU - Kyong Nam, Kim
AU - Yong Chun, Ko
SN - 1017-2548
TI - Differential Pulse Voltammetric Determination of Iron(II) ion with a Nafion-Ethylenediamine Modified Glassy Carbon Electrode
VL - 47
PB - Korean Chemical Society
DO - 10.5012/jkcs.2003.47.2.115
PY - 2003
UR - http://dx.doi.org/10.5012/jkcs.2003.47.2.115
ER -
Kyong Wone, K.
,
Hee Cheol, K.
,
Sung-Hyun, K.
,
Byung Ho, P.
,
Yeon Hee, K.
,
Kyong Nam, K.
,
&
Yong Chun, K.
( 2003).
Differential Pulse Voltammetric Determination of Iron(II) ion with a Nafion-Ethylenediamine Modified Glassy Carbon Electrode.
Journal of the Korean Chemical Society,
47
(2)
Korean Chemical Society.
doi:10.5012/jkcs.2003.47.2.115
Kyong Wone, K
et al.
2003,
Differential Pulse Voltammetric Determination of Iron(II) ion with a Nafion-Ethylenediamine Modified Glassy Carbon Electrode,
Journal of the Korean Chemical Society,
vol. 2,
no. 2,
Retrieved from http://dx.doi.org/10.5012/jkcs.2003.47.2.115
[1]
K Kyong Wone
,
K Hee Cheol
,
K Sung-Hyun
,
P Byung Ho
,
K Yeon Hee
,
K Kyong Nam
,
and
K Yong Chun
,
“Differential Pulse Voltammetric Determination of Iron(II) ion with a Nafion-Ethylenediamine Modified Glassy Carbon Electrode”,
Journal of the Korean Chemical Society,
vol. 2,
no. 2,
Apr
2003.
Kyong Wone, Kim
Hee Cheol, Kim
Sung-Hyun, Kim
et al.
“Differential Pulse Voltammetric Determination of Iron(II) ion with a Nafion-Ethylenediamine Modified Glassy Carbon Electrode”
Journal of the Korean Chemical Society,
2.
2
2003:
Kyong Wone, K
,
Hee Cheol, K
,
Sung-Hyun, K
,
Byung Ho, P
,
Yeon Hee, K
,
Kyong Nam, K
,
Yong Chun, K
Differential Pulse Voltammetric Determination of Iron(II) ion with a Nafion-Ethylenediamine Modified Glassy Carbon Electrode.
Journal of the Korean Chemical Society
[Internet].
2003.
Apr ;
2
(2)
Available from http://dx.doi.org/10.5012/jkcs.2003.47.2.115
Kyong Wone, Kim
,
Hee Cheol, Kim
,
Sung-Hyun, Kim
,
Byung Ho, Park
,
Yeon Hee, Kim
,
Kyong Nam, Kim
,
and
Yong Chun, Ko
,
“Differential Pulse Voltammetric Determination of Iron(II) ion with a Nafion-Ethylenediamine Modified Glassy Carbon Electrode.”
Journal of the Korean Chemical Society
2
no.2
()
Apr,
2003):
http://dx.doi.org/10.5012/jkcs.2003.47.2.115