Power Tracking Control of Domestic Induction Heating System using Pulse Density Modulation Scheme with the Fuzzy Logic Controller
Power Tracking Control of Domestic Induction Heating System using Pulse Density Modulation Scheme with the Fuzzy Logic Controller
Journal of Electrical Engineering and Technology. 2014. Nov, 9(6): 1978-1987
Copyright © 2014, The Korean Institute of Electrical Engineers
  • Received : December 26, 2013
  • Accepted : June 06, 2014
  • Published : November 01, 2014
Download
PDF
e-PUB
PubReader
PPT
Export by style
Article
Author
Metrics
Cited by
TagCloud
About the Authors
Booma Nagarajan
Corresponding Author: Dept. of Electrical and Electronics Engineering, Jerusalem College of Engineering, Chennai, India. (booma_nagarajan@yahoo.com)
Rama Reddy Sathi
Dept. of Electrical and Electronics Engineering, Jerusalem College of Engineering, Chennai, India. (srr.victory@gmail.com)
Pradeep Vishnuram
Dept. of Electrical and Electronics Engineering, Jerusalem College of Engineering, Chennai, India. (pradeep.kannan03@gmail.com)

Abstract
Power requirement to the induction heating system varies during the heating process. A closed loop control is required to have a smooth control over the power. In this work, a constant frequency pulse density modulation based power tracking control scheme for domestic induction heating system is developed using the Fuzzy Logic Controller. In the conventional power modulation schemes, the switching losses increase with the change in the load. The proposed pulse density modulation scheme maintains minimum switching losses for the entire load range. This scheme is implemented for the class-D series resonant inverter system. Fuzzy logic controller based power tracking control scheme is developed for domestic induction heating power supply for various power settings. The open loop and closed loop simulation studies are done using the MATLAB/Simulink simulation tool. The control logic is implemented in hardware using the PIC16F877A microcontroller. Fuzzy controller tracks the set power by changing the pulse density of the gate pulses applied to the inverter. The results obtained are used to know the effectiveness of the fuzzy logic controller to achieve the set power.
Keywords
1. Introduction
Induction heating (IH) load requires high frequency power supply to induce high frequency eddy currents in the work-piece which result in heating effect. IH technique is used to produce high temperature for domestic cooking and many industrial applications like steel melting, brazing and surface hardening. For these applications, the operating frequency must be selected based on the work-piece geometry and skin depth requirements [1] . Advanced technology in development of the high frequency semiconductor switches has made it possible to introduce new switching devices with sophisticated functions in a smaller size at a lower price. Recent developments in power electronic devices and switching schemes have made the voltage source fed series resonant inverter (SRI) suitable for IH applications [2 - 4] . Different modulation schemes for the resonant inverters are developed to vary the output power. The output power can be controlled by varying the switching frequency using pulse frequency modulation (PFM) technique [5 - 8] . The phase shift (PS) control technique varies the output power by phase shifting the pulses applied to the power switches of the inverter [9 - 11] . The asymmetrical duty cycle (ADC) control technique employs an unequal duty operation of the switches in the inverter. Accuracy in the output power control is very important in IH applications. For example, domestic cooking appliances require accurate power control over a wide range of load with high efficiency. To improve the efficiency of SRI, zero voltage switching (ZVS) operating condition must be maintained over the entire load range. In the conventional fixed frequency modulation techniques, the ZVS condition is ensured only for limited range of duty cycle [12] . In the above mentioned methods, the output power control is difficult due to the variation of IH load parameters during the heating process [13 - 15] . With the variation in load parameters, non-ZVS operating condition results during the switching operation which causes more power losses [16 , 17] . The above literature does not deal with the power tracking control of domestic induction cooking system using pulse density modulation (PDM). The PDM technique regulates the output power by varying the period in which the inverter injects high frequency current to the induction coil. For the load range of (0- 100) %, the ZVS condition is maintained in the PDM based control scheme. This power control scheme satisfies the variable power requirement of the load with the minimum switching losses. Since the switching frequency is not varied, the switching loss is minimum and constant throughout the entire load range. This paper discusses the power control of class-D SRI using PDM technique in open loop and closed loop operation. In the closed loop operation, fuzzy logic controller (FLC) based power tracking of the various power settings is proposed. The PID controller based conventional scheme is replaced with the FLC. The closed loop operation ensures the tracking of reference power set by the user in their induction cooking system.
2. Description of the Power Converter
The Fig. 1 shows the main circuit diagram of the class-D SRI fed IH load. Uncontrolled rectifier is used to convert the single phase AC input voltage (V i ) of 50 Hz frequency into DC. In order to filter the ripple content, a DC link capacitor (C B ) is used. Then the DC input voltage (V B ) is given to the inverter to produce high frequency AC which is essential for IH system. This high frequency AC current (i o ) is applied to the IH coil, and the pan gets heated up. R eq and L eq are the equivalent resistance and inductance of the IH coil and the pan. The resonant operating condition is achieved using a resonant capacitor (C r ) which is considered equally on both sides of the bridge. The switches Q 1 and Q 2 are the MOSFET switches with antiparallel diodes. These switches are alternatively turned on/off with the high frequency PDM pulses generated by the FLC based control scheme to produce the reference power set by the user.
PPT Slide
Lager Image
Schematic diagram of the IH power supply system with the FLC based control scheme
3. Principle of PDM Technique
In PDM technique, the switching frequency of the inverter is kept constant and it is chosen slightly greater than the load resonant frequency in order to reduce the switching losses. The logic circuit for the generation of the PDM based pulses is shown in Fig. 2 . High frequency 25 kHz pulses are logically compared with the low frequency 20 Hz pulses. Pulses for the switches Q 1 and Q 2 are generated when the low frequency signal goes high as given in Fig. 3 . When the low frequency pulse goes low, the switches Q 1 and Q 2 do not receive the gate pulses and they remain in, off condition.
PPT Slide
Lager Image
Gate pulse generation circuit for the switches of the inverter
PPT Slide
Lager Image
Generation of the PDM pulses for the switches Q1 and Q2
Waveforms for the output voltage (V o ) and the output current (I o ) of SRI with PDM control are given in Fig. 4 .
PPT Slide
Lager Image
Key waveforms of the SRI with the PDM control.
From the waveforms, it can be observed that the envelope of the current follows a first-order response even though the inverter system is a second order system. For the control of output power, it is important to analyze the output power of the inverter with PDM control. The envelope of the current (i E ) is given by,
PPT Slide
Lager Image
PPT Slide
Lager Image
PPT Slide
Lager Image
Where, T PDM is the total control period for PDM operation and T ON is the total on period of the switch. I is the initial value of the envelope i E and I m is the maximum current at the rated power operation of the inverter. The amplitude of the i E is directly proportional to the pulse density.
PPT Slide
Lager Image
In PDM based SRI, the average output power (P) is obtained by multiplying V B and i E as follows,
PPT Slide
Lager Image
PPT Slide
Lager Image
With T PDM >> τ, the output power is in proportion to the pulse density as given below.
PPT Slide
Lager Image
During every mask period of the pulses, the freewheeling of resonant current takes place in the load side such that the energy stored in the inductor and capacitor is dissipated in the load. The PDM duty cycle (D PDM ) is given by,
PPT Slide
Lager Image
The D PDM must be selected such that the low frequency signal must be less than 20 Hz to avoid acoustic noise. The average output power (P o ) can be calculated in terms of D PDM using the following equation.
PPT Slide
Lager Image
Where, P rated is the output power with D PDM equal to one. The output power could be controlled by controlling the D PDM . Since the switching frequency is constant, even with the variation in D PDM , the turn on and turn off instants of the switches are not varied in PDM method. Hence the ZVS condition is maintained throughout the load cycle. This reduces the switching losses in the high frequency SRI.
4. Simulation Results
- 4.1 Open loop study of IH system with PDM control
The simulink model of the open loop system with class-D resonant inverter is shown in Fig. 5 . The parameters used for the simulation are listed below: f s =25 kHz, R eq =5 Ω, L eq =0.3 mH, C r /2=0.65μF, P rated =100 W. The PDM pulses for the switches Q 1 and Q 2 are generated as discussed earlier. By varying the D PDM of the low frequency signal, the output power can be controlled. The rated output power is obtained for the D PDM of 100%. To prove the variation in power with the D PDM signal, the simulation is carried out for duty cycles of 70% and 30% respectively. For the rated power of 100W, the high switching frequency (f s ) and the low frequency (f PDM ) are chosen as 25 kHz and 20 Hz respectively. Fig. 6(a) illustrates the output voltage waveform with 70% of D PDM .
PPT Slide
Lager Image
Simulink model of the open loop system
PPT Slide
Lager Image
Simulation Results (a) Output voltage waveform with 70% of DPDM (b) Output current waveform with 70% of DPDM (c) Output power waveform with 70% of DPDM (d) Average output power with 70% of DPDM
The output current and the real power for 70% of D PDM are presented in Figs. 6(b) and Fig. 6(c) respectively. Since the voltage and current are in discontinuous form, the average value of the power is measured and it is shown in Fig. 6(d) . When the D PDM is 70%, the average current and the voltage get lowered due to the discontinuous flow of V o and I o . This causes the reduction of the average output power from 100 W to 70 W. Similarly the switches are operated with D PDM of 30% and the corresponding waveforms of output voltage, output current , instantaneous power and average output power are shown in Figs. 7(a) , 7(b) , 7(c) and 7(d) respectively. The average power is about 30W with 30% D PDM. The output voltage is a high frequency waveform and hence the driving pulses to the switches, the zoomed view of the voltage and current are shown in Figs 7(e) , 7(f) and 7(g) respectively. The average output power changes linearly with the change in the value of the D PDM, in PDM technique. It has been found from the simulation results that, by controlling the D PDM from 0% to 100%, the average value of the output power can be controlled.
PPT Slide
Lager Image
Simulation Results(a) Output voltage waveform with 30% of DPDM (b) Output current waveform with 30% of DPDM (c) Output power waveform with 30% of DPDM (d) Average output power waveform with 30% of DPDM (e) Driving pulses to the switches Q1 and Q2 (f) Zoomed view of the Output voltage (g) Zoomed view of the output current
- 4.2 FLC based power control of IH load
In domestic IH system, according to the heating requirement, the power setting is changed by the user. Different modulation schemes are available to perform power control for IH load. This section discusses the development of FLC for the power control of IH system using PDM technique.
Fuzzy logic is a nonlinear control technique, which is applied to the control of converters to improve the performance of the system as suggested in literature [18 - 20] . Expert knowledge plays a vital role in designing the FLC and it could be used in the system which has large variations of input voltage or load. The performance of the controller is evaluated by the number of linguistic variables, the control range of linguistic variable and the slope of membership function. The fuzzy controller is robust to the variations in input DC voltage and load. FLC does not require the mathematical model of the system / process as like conventional controller but it is necessary to understand the system / process and the control requirements.
The information / data (control input variable) flows must be designed by the fuzzy controller designer, then the information / data is processed (control strategy and decision), and the corresponding control data flows out of the system (solution / output variable). The major development of fuzzy logic was primarily designed to represent and reason with some particular form of knowledge. The basic configuration of the fuzzy logic system is shown in Fig. 8 .
PPT Slide
Lager Image
Block diagram of FLC
The operation of the FLC involves three modules. They are fuzzification interface, knowledge based fuzzy reasoning mechanism and defuzzification modules to produce the control signal necessary for the plant. Fuzzy reasoning mechanism is used to convert the measured crisp values into fuzzy linguistic values. This process is called as fuzzification. In order to achieve the control goal, the collections of expert’s control rules (knowledge) are needed. They are called as knowledge base. In this process, the fuzzy logic operations and the control actions are taken according to the fuzzy inputs. The process of converting the fuzzified values into the crisp value is called as defuzzification. The centre of area or centroid defuzzification is the most frequently used defuzzification technique which is also used in this work and is characterized by
PPT Slide
Lager Image
Where y represents the crisp value of the output of the fuzzy controller and μ is its membership grade. The MATLAB Simulink tool is used to test the performance of the FLC in the output power control of IH load. The output power needs to be varied according to the reference value set by the user. This is an important objective of the FLC based closed loop system considered in this work.
The simulink model of the closed loop control using FLC is shown in Fig. 9 . The mean power is measured and compared with the set power to find the error (e). The inputs to the FLC are the error and the derivative of the error (Δe) in power. The output of the controller is the control signal used to vary the D PDM. The two inputs and one output of FLC are divided into five triangular membership functions as shown in Fig. 10(a) .
PPT Slide
Lager Image
Simulink model of the FLC based closed loop controlled IH power supply system.
PPT Slide
Lager Image
(a) Membership function of the input and output variables of the FLC (b) Surface plot for error, change in error and control variable
With the basic control knowledge of diverging and converging system, the control action involved is based on the simple linguistic rules which are listed below.
  • 1) If the error is large, change of DPDMmust be large to bring the output equal to the reference power.
  • 2) If the error is near zero, small change of DPDMis needed.
  • 3) If the error is near zero and the derivative of error is large, the DPDMshould be kept constant.
  • 4) When the set point is reached and the output still changes, a very small change in DPDMis necessary to prevent the output moving away from the required value.
The surface plot which shows the variation of the controller output corresponding to the e and Δe is shown in Fig. 10 (b) .
The rule base is developed for FLC scheme with the above points as reference and they are listed in Table 1 . The flowchart of the FLC based power control is shown in Fig. 11 . The control signal produced by the controller, based on the rule base is used to generate the PDM gate signals to the switches. The FLC is designed such that it tracks the reference power by changing the D PDM of the PDM signals.
Fuzzy rule base
PPT Slide
Lager Image
Fuzzy rule base
PPT Slide
Lager Image
Flow chart for the FLC based power control
The control signal at the output of the PID controller is U(s) and it can be defined as
PPT Slide
Lager Image
Where K p , K i and K d are the proportional, integral and derivative gains of the PID controller for the given operating conditions. For the set power of 25 W, the values of the K p , K i and K d are equal to 0.9, 1.6 and 2.3 respectively. The gains of the PID controller are obtained using Ziegler and Nichols method. The control signal U(s) is used to produce the PDM based gate signals necessary to track the output power.
Figs. 12(a) and (b) illustrate the response of the system with the PID controller and FLC for the set power of 25 W and 100 W respectively. For the given values of the gains, the PID controller tracks the output power only for the set power of 25W. It has been found from the simulation study that the the PID controller requires different values of the gains when the set power is varied.
PPT Slide
Lager Image
(a) Response with PID controller and FLC for set power of 25W (b) Response with PID controller and FLC for set power of 100 W (c) Response of the system with FLC for variation of the power from 100 W to 0 W
The variation of output power from 100 W to 0 W using the FLC is shown in Fig. 12 (c) . The green line indicates the reference power. For every 0.5s, the reference power setting is made to decrease by 25 W from the rated power of 100W. The red line indicates the actual power of the inverter. It can be noted that the output power follows the reference power. Both the controllers track the reference power with zero steady state error. The effectiveness of the FLC can be studied using the settling time (t s ). The comparison of the system using the conventional and the proposed controller for different values of set power are given in Table 2 .
Comparison of the performance parameters with the PID and fuzzy logic controllers
PPT Slide
Lager Image
Comparison of the performance parameters with the PID and fuzzy logic controllers
The PID controller and FLC system reach the steady state with the settling time of 0.44s and 0.075s respectively for the reference power of 25 W. Thus a fast and smooth transition of power control is possible using the FLC without any oscillation. It is also observed that the proposed FLC tracks the output power for the entire power range whereas the PID controller requires tuning of the controller for every set value due to the nonlinear nature of the load.
5. Experimental Results
A prototype of high frequency AC power supply circuit rated for 100 W was fabricated to validate the control scheme in class D inverter circuit. The simulation results of the IH power supply system using the proposed control technique are validated using the experimental results. The hardware layout of the system and the test setup of the system are shown in Figs.13(a) and 13(b) respectively. The full bridge uncontrolled rectifier was constructed using the four IN5408 diodes to supply DC to the class D inverter. The class D inverter was constructed using two IRF840 MOSFET switches for the conversion of DC into high frequency AC.
PPT Slide
Lager Image
Hardware Results (a) Hardware layout of the IH power supply system (b) Test set up of the Hardware (c) Driving pulses to the switches Q1 and Q2 (X axis 1cm = 2V, Y axis 1 cm=100 μs) (d) Output Voltage (X axis 1cm= 30V, Y axis 1 cm=100 μs) (e) Output current (X axis 1cm= 2A, Y axis 1 cm=200 μs) (f) Response of the system with FLC for set power of 25W (X axis 1cm= 15 W, Y axis 1 cm=100 μs).
The control circuit for the PDM control strategy is implemented using a PIC16F877A micro controller. The micro controller produces the PDM pulses required by the switches Q 1 and Q 2 . The pulses from the controller are amplified using IR2110 driver. It also provides the isolation between the power circuit and the control circuit. The output pulses from the driver circuit are shown in Fig. 13(c) . The output voltage and current of SRI with D PDM of 25% are shown in Figs. 13(d) and 13(e) respectively. The current is measured using SIGLENT CP4060 type current probe. The waveforms are recorded using the RIGOL DS1052E type digital oscilloscope. The response of the system with FLC is shown in Fig. 13 (f) . It can be observed that these oscillograms follow the theoretical and simulation results discussed in the previous sections. The obtained results confirm that the FLC track the set power with less settling time.
6. Conclusion
In this paper, the high-frequency IH power supply system is discussed with PDM technique and the power control is done using the FLC. The open and closed loop circuit models with PDM control are developed and they are successfully used for the simulation studies. The detailed study on PDM based SRI confirms the power control through the PDM duty cycle variation without the change in frequency. Experimental verification is also done through the PIC16F877A microcontroller. The PDM operation maintains soft switching condition for the entire load cycle. The closed loop control using PDM based FLC confirms that it tracks the reference power for the whole range of operation with different power settings. The proposed FLC system provides fast response. However, it requires the complete knowledge of the system to develop the rule base. The hardware response of the inverter system can be improved by replacing the PIC controller with DSP controller.
BIO
Booma Nagarajan She is a research scholar in the Department of Electrical and Electronics Engineering, Jerusalem College of Engineering, Centre for Collaborative Research, Chennai, India. She obtained her D.E.E.E from Thiagarajar Polytechnic, Salem; T.N in 1997.She received her B.E degree in Electrical Electronics Engineering from Madras University, Chennai, India in 2000, M.E. degree in Power Systems Engineering from College of Engineering, Guindy, Anna University, Chennai, India in 2007. She has 13 years of teaching experience. She has published over 22 Technical papers in National and International Conferences Proceedings / Journals. Her research interests include resonant inverters for induction heating intelligent controllers and power quality.
Rama Reddy Sathi He is professor in the Department of Electrical & Electronics Engineering Department, Jerusalem College of Engineering, Chennai, India. He obtained his D.E.E.E from S.M.V.M. polytechnic, Tanuku, A.P., A.M.I.E. in Electrical Engineering from Institution of Engineers (India), M.E. in Power Systems from Anna University, Chennai and Ph.D in the area of Power Electronics from Anna University, Chennai, India. He has published over 80 Technical papers in National and International Conferences proceedings / journals. He has secured A.M.I.E. Institution gold medal for obtaining the highest marks. He has secured AIMO best project award and ISTE National level Best teacher Award. He has 20 years of teaching experience. His research interests include the areas of resonant converters and FACTS. He has received funds for MODROBS and Research and development from All India Council of Technical Education (AICTE) He is a life member of the Institution of Engineers (India), Indian Society for Technical Education, Systems Society of India, Society of Power Engineers and Institution of Electronics and Telecommunication Engineers (India).
Pradeep Vishnuram He is Assistant professor in Jerusalem college of Engineering, Chennai, India. He received his B.E degree in Electrical and Electronics Engineering from J. J College of Engineering and Technology, Trichy, Tamil Nadu in 2012. His interests include the resonant converters for induction heating, intelligent controllers and high power factor rectifiers.
References
Acero J. , Burdío J. M. , Barragán L.A. , Navarro D. , Alonso R. , Garcia J. R. , Monterde F. , Hernández P. , Llorente S. , Garde I. 2008 “The domestic induction heating appliance: An overview of recent research” Proc. Appl. Power Electron. Conf. Expo. 651 - 657
Lucía O. , Burdío J. M. , Millán I. , Acero J. , Barragán L. A. 2010 “Efficiency oriented design of ZVS halfbridge series resonant inverter with variable frequency duty cycle control” IEEE Transactions on Power Electronics 25 (7) 1671 - 1674    DOI : 10.1109/TPEL.2010.2042461
Sarnago H. , Mediano A. , Lucia O. 2012 “High efficiency ac-ac power electronic converter applied to domestic induction heating” IEEE Transactions on Power Electronics 27 (8) 3676 - 3684    DOI : 10.1109/TPEL.2012.2185067
Saha B. , Soon Kurl K. , Ahmed N. A. , Omori H. , Nakaoka M. 2008 “Commercial frequency AC to high frequency AC converter with boost-active clamp bridge single stage ZVS-PWM inverter” IEEE Transactions on Power Electronics 23 (1) 412 - 419    DOI : 10.1109/TPEL.2007.911871
Park N. J. , Lee D. Y. , Hyun D. S. 2007 “A powercontrol scheme with constant switching frequency in class-D inverter for induction-heating jar application” IEEE Transactions on Industrial Electroics 54 (3) 1252 - 1260    DOI : 10.1109/TIE.2007.892741
Lucía O. , Burdío J. M. , Barragán L. A. , Acero J. , Carretero C. 2011 “Series resonant multi-inverter with discontinuous-mode control for improved light-load operation” IEEE Transactions on Industrial Electronics 58 (11) 5163 - 5171    DOI : 10.1109/TIE.2011.2126541
Esteve V. , Sanchis-Kilders E. , Jordán J. , Dede E. J. , Cases C. , Maset E. , Ejea J. B. , Ferreres A. 2011 “Improving the efficiency of IGBT series resonant inverters using pulse density modulation” IEEE Transactions on Industrial Electronics 58 (3) 979 - 987
Lucia O. , Burdio J. M. , Millan I. , Acero J. , Barragan L. A. 2010 “Efficiency-oriented design of ZVS half-bridge series resonant inverter with variable frequency duty cycle control” IEEE Transactions on Power Electronics 25 (7) 1671 - 1674    DOI : 10.1109/TPEL.2010.2042461
Ahmed N. A. , Nakaoka M. 2006 “Boost-half-bridge edge resonant soft switching PWM high-frequency inverter for consumer induction heating appliances” IEE Proc. Electr. Power Appl. 153 (6) 932 - 938    DOI : 10.1049/ip-epa:20060086
Pham H. , Fujita H. , Ozaki K. , Uchida N. 2011 “Phase angle control of high-frequency resonant currents in a multiple inverter system for zone-control induction heating” IEEE Transactions on Power Electronics 26 (11) 3357 - 3366    DOI : 10.1109/TPEL.2011.2146278
Carretero C. , Lucia O. , Acero J. , Burdio J. M. 2011 “Phase-shift control of dual half-bridge inverter feeding coupled loads for induction heating purposes” Electronics Letters 47 (11) 670 - 671    DOI : 10.1049/el.2011.1114
Lucía O. , Burdío J. M. , Millán I. , Acero J. , Puyal D. 2009 “Load-adaptive control algorithm of halfbridge series resonant inverter for domestic induction heating” IEEE Transactions on Industrial Electronics 56 (8) 3106 - 3116
Byun J. K. , Choi K. , Roh H. S. , Hahn S. Y. 2000 “Optimal design procedure for a practical induction heating cooker” IEEE Trans. Magn. 36 (4) 1390 - 1393    DOI : 10.1109/20.877698
Lucia O. , Carretero C. , Palacios D. , Valeau D. , Burdio J. M. 2011 “Configurable snubber network for efficiency optimization of resonant converters applied to multi-load induction heating” Electronics Letters. 47 (17) 989 - 991    DOI : 10.1049/el.2011.1711
Lucía O. , Barragán L. A. , Burdío J. M. , Jiménez O. , Navarro D. , Urriza I. 2011 “A versatile power electronics test-bench architecture applied to domestic induction heating” IEEE Transactions on Industrial Electronics 58 (3) 998 - 1007    DOI : 10.1109/TIE.2010.2048840
Tschirhart D. J. , Jain P. K. 2008 “A CLL resonant asymmetrical pulse width modulated converter with improved efficiency” in IEEE Transactions on Industrial Electronics 55 (1) 114 - 122    DOI : 10.1109/TIE.2007.906176
Viriya P. , Yongyuth N. , Matsuse K. 2008 “Analysis of two continuous control regions of conventional phase shift and transition phase shift for induction heating inverter under ZVS and non-ZVS” in IEEE Transaction on Power Electronics 23 (6) 2794 - 2804    DOI : 10.1109/TPEL.2008.2004037
Balestrino A. , Landi L. Sani 2002 “CUK converter global control via fuzzy logic and scaling factor” IEEE Transactions on Industrial Electronics 38 (2) 406 - 413
Vidal E. , Martine L. , Guinjoan F. , Calvente J. , Gomariz S. 2004 “Sliding and fuzzy control of a boost converter using an 8-bit microcontroller” Proc. Inst. Elect. Eng., Electr. Power Appl. 151 (1) 5 - 11    DOI : 10.1049/ip-epa:20040086
Gupta T. , Boudreaux R. R. 1997 “Implementation of a fuzzy controller for DC-DC converters using an inexpensive 8-bit micro-controller” IEEE Transactions on Industrial Electronics 44 (5) 661 - 669    DOI : 10.1109/41.633467